Vasa previa is rare, but it can cause an emergency when fetal blood vessels located near the birth canal rupture. Unlike blood vessels protected within the umbilical cord or placenta, vessels in this condition run through the amniotic membranes. Therefore, detecting the condition before delivery is an important part of efforts to protect both mother and baby.

This was the focus of a systematic review conducted by Dudy Aldiansyah and 24 other researchers. They examined evidence on screening, pregnancy management, delivery timing, and maternal and neonatal outcomes. Searches were conducted across several medical databases and clinical trial registries through March 2025. A total of 25 studies involving more than 3,000 pregnancies were included in the review.

Blood Vessels That Need to Be Detected Before Delivery

In pregnancies complicated by vasa previa, some fetal blood vessels pass near or over the cervix without the protection normally provided by the placenta or umbilical cord. If the amniotic membranes rupture during labor, these vessels are at risk of tearing as well. The resulting bleeding comes from the fetus, making this condition one that must be recognized and managed by healthcare professionals.

This review highlights transvaginal ultrasound combined with color Doppler during the second-trimester fetal anatomy scan. Transvaginal ultrasound helps visualize the area near the cervix, while color Doppler displays blood flow, allowing the position of the vessels to be assessed. In the studies summarized, this universal screening approach reported sensitivity above 90%. Screening limited to pregnancies with specific risk factors may potentially miss some cases. This figure represents the findings of the reviewed studies, not a guarantee that every examination at every healthcare facility will produce the same result.

Determining Delivery Timing While Considering Fetal Maturity

Once vasa previa has been identified, the medical team needs to plan delivery to prevent the vulnerable blood vessels from being exposed to risk during labor. However, delivery that occurs too early can also increase risks associated with prematurity.

In the summarized evidence, planned cesarean delivery at 36–37 weeks of gestation was associated with better neonatal outcomes than earlier delivery, while also reducing the risk of prematurity resulting from intervention that occurs too soon. Delivery timing still needs to be determined based on the pregnancy's condition and the assessment of the attending doctor; the timing discussed in this review is not an automatic schedule for every patient.

The review also discusses inpatient care and outpatient monitoring. The comparative studies did not show a clear increase in adverse outcomes among carefully selected outpatients, provided that strict monitoring criteria and rapid access to surgical facilities were available. This means that decisions about where to monitor the pregnancy need to take the patient's condition and the readiness of local healthcare services into account.

Fetoscopy Is Still at the Research Stage

The researchers also discussed fetoscopy, a procedure that uses a thin instrument equipped with a camera to view the inside of the uterus. One approach currently being explored involves closing off or ablating exposed blood vessels using a laser.

Evidence regarding this procedure is still limited to case reports and small case series. The procedure is considered technically feasible, but the reviewed studies also noted risks such as premature rupture of the amniotic membranes, bleeding, and fetal loss. Therefore, fetoscopy for vasa previa remains experimental and should be performed in specialized research settings. This review identifies screening and delivery planning as the approaches currently supported by stronger evidence.

Early Detection Helps Prepare for Delivery

This review highlights that examining the positions of the placenta, umbilical cord, and blood vessels around the cervix can help detect vasa previa before delivery. If the condition is identified early, healthcare professionals can plan monitoring and delivery timing while considering the safety of both mother and baby.

For pregnancy care services, these findings support consideration of more comprehensive screening during the second-trimester fetal anatomy ultrasound. Subsequent plans should still be tailored to the examination results and the condition of each pregnancy, in consultation with the attending doctor.

Key Research Points

  • The study focuses on evidence regarding screening, management, and pregnancy outcomes in cases of vasa previa detected before delivery.

  • The method involved a systematic review following the PRISMA 2020 guidelines, with searches of medical databases and clinical trial registries through March 2025.

  • The reviewed evidence included 25 studies involving more than 3,000 pregnancies, including clinical trials, cohort studies, systematic reviews, and case series.

  • Screening findings showed that transvaginal ultrasound combined with color Doppler during the second-trimester fetal anatomy scan had sensitivity above 90% in the summarized studies.

  • Delivery-related findings associated planned cesarean delivery at 36–37 weeks of gestation with better neonatal outcomes than earlier delivery.

  • Outpatient care may be considered for carefully selected patients, provided that close monitoring and rapid access to surgical facilities are available.

  • Fetoscopy is still supported by limited evidence and carries procedural risks, so this approach remains within the scope of specialized research.