A Hole in the Heart's Wall Can Be Closed Without Open-Heart Surgery
Some people have a hole in the wall separating the two upper chambers of the heart. This condition is called an atrial septal defect or ASD. If the shape and location of the hole are suitable, doctors can close it using a small device inserted through a thin tube from a blood vessel in the groin to the heart.
Doctors usually use fluoroscopy—X-ray imaging that displays the movement of instruments during the procedure—to see the positions of the tube and closure device. The team at the Heart Centre of Haji Adam Malik General Hospital Medan studied their experience using ultrasound guidance through the esophagus to visualize the heart and guide the device, allowing the procedure to be performed without fluoroscopy.
Ultrasound Through the Esophagus Helps Visualize the Heart
In this procedure, an ultrasound probe is inserted through the mouth into the esophagus. Because the esophagus is located close to the heart, the resulting images help doctors visualize the hole, the surrounding tissue, and the position of the closure device throughout the procedure.
This technique aims to reduce X-ray exposure from fluoroscopy for patients and medical personnel. However, the procedure still requires careful preparation and monitoring. In this study, patients underwent general anesthesia, and doctors first assessed whether the shape of the hole and the surrounding tissue were suitable for device closure.
Experience with 116 Patients in Medan
The researchers reviewed the medical records of patients who underwent the procedure at Haji Adam Malik General Hospital between May 2020 and August 2024. Of the 116 patients with types of ASD suitable for device closure, the procedure could be performed without fluoroscopy in most patients. Five procedures required fluoroscopic assistance because the ultrasound images did not provide a sufficiently clear view.
The authors reported a success rate of approximately 95% for the fluoroscopy-free technique. One patient experienced fluid accumulation around the heart, which was successfully managed. The procedures took an average of approximately 56 minutes. These findings are based on the experience of a single healthcare center with a team accustomed to performing the procedure and interpreting cardiac ultrasound images.
Patient Selection and Team Expertise Remain Important
Not all holes in the heart's wall are suitable for this technique. Doctors need to ensure that the size and position of the hole, as well as the surrounding tissue, adequately support the closure device. If the ultrasound images are unclear or the patient's condition makes a fluoroscopy-free procedure less safe, the team can use fluoroscopic assistance or consider other treatment options.
Clear ultrasound images and coordination between the doctor performing the procedure and the cardiac imaging specialist are important parts of the procedure. The hospital must also be prepared to manage complications if they occur. Therefore, the findings of this study describe what an experienced team at this particular center can achieve, rather than guaranteeing that the same technique can be applied to every patient or healthcare facility.
Reducing X-Ray Exposure While Maintaining Safety
These findings provide an overview of how ultrasound guidance can help close certain types of heart defects without fluoroscopic exposure in many patients treated by the team in Medan. Its potential benefit is reducing X-ray exposure during the procedure.
However, the goal of reducing exposure must go hand in hand with the priority of patient safety. If ultrasound images are inadequate, using fluoroscopy as an aid is part of the team's decision to complete the procedure safely. This study is observational and based on the experience of a single hospital; further patient follow-up is needed to gain a more complete understanding of long-term outcomes.
Key Research Points
This study reviewed the experience of closing a hole in the heart's wall using a device inserted through a blood vessel.
Doctors used ultrasound through the esophagus to visualize the heart and guide the device without fluoroscopy in suitable patients.
The data covered 116 patients at Haji Adam Malik General Hospital Medan who were scheduled to undergo the procedure between May 2020 and August 2024.
Five procedures required fluoroscopic assistance because the ultrasound images were not sufficiently clear.
The authors reported a success rate of approximately 95% and one complication involving fluid around the heart, which was successfully managed.
This technique requires appropriate patient selection, adequate ultrasound images, and an experienced team.
Because the study came from a single healthcare center and involved a review of patient records, the findings do not yet represent outcomes at all hospitals or in all patients with ASD.
News Writer
Khairul Azmi
Source
dr. Ali Nafiah Nasution, M.Ked(Cardio), Sp.JP(K), FIHA